Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 10.431
Filtrar
1.
J Orthop Surg Res ; 19(1): 206, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38561763

RESUMO

BACKGROUND: Reports show a high complication rate when starting with the Direct Anterior Approach (DAA) in a supine position for hip arthroplasty. The DAA with the patient in lateral decubitus position may avoid this problem because it supposedly provides better visibility, especially on the femoral side. However, this approach did show a rather high complication rate during the adoption of the approach at 1 year follow up in our previous report. We were interested what the overall 7 year survival estimate would be and whether improvement could be seen with growing experience. METHODS: A cohort of patients undergoing total hip arthroplasty right from the start of applying the DAA in lateral decubitus position was analysed. RESULTS: In total 175 hip prostheses (162 patients) were evaluated. The 7-year survival estimate was 95.1%, 95 CI: 91.8-98.4%. In 6 of 8 revisions there was aseptic loosening of the stem. By dividing the cohort into 3 consecutive groups in time we did not see a significantly improving revision rate. CONCLUSIONS: In our experience, the adoption of the direct anterior approach in lateral decubitus position caused a relatively low 7-year survival estimate without an apparent decrease with growing experience, however given the low number of cases further research is needed to investigate the long-term risk of adopting a new approach.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Humanos , Estudos Retrospectivos , Artroplastia de Quadril/efeitos adversos , Artroplastia de Quadril/métodos , Fêmur/cirurgia , Reoperação
2.
BMC Musculoskelet Disord ; 25(1): 259, 2024 Apr 02.
Artigo em Inglês | MEDLINE | ID: mdl-38566097

RESUMO

BACKGROUND: Modular neck femoral stems are advantageous because they can accurately restore the ideal hip geometry using various options in terms of offset, length, and version. However, there are concerns regarding junctional problems. Despite several reports on such issues, there is a lack of study on mid- to long-term results of these stems. The current study evaluated the mid-term results of patients who underwent primary total hip arthroplasty using a titanium-titanium (Ti-Ti) modular neck femoral stem. METHODS: In total, data on 47 hips (42 patients) that could be followed-up for ≥ 5 years after primary total hip arthroplasty using the Ti-Ti modular neck femoral stem from 2011 to 2015 were reviewed. There were 22 male and 20 female patients, and their mean age was 56.3 (range: 31-76) years. The mean follow-up period was 8 (range: 5-12) years. Functional and radiological outcomes, complications, and reoperations were investigated. In addition, we conducted a comparative analysis of the outcomes between those who underwent surgery using the Ti-Ti modular neck femoral stem and 41 hips (35 patients, 19 males and 16 females) that underwent primary total hip arthroplasty using nonmodular femoral stems as a control. RESULTS: In all Ti-Ti cases, the mean Harris Hip Scores were 50.6 (range: 6-59) preoperatively and 92.7 (range: 78-99) at the last follow-up (P < 0.001). Regarding the neck component's modularity, straight neck components were used in all Ti-Ti cases, and an anteverted or a retroverted neck was not used in any case. Stem revision was performed in one hip due to aseptic loosening. One hip underwent open reduction and internal fixation due to periprosthetic fracture without stem loosening. There were no cases of osteolysis and periprosthetic joint infection and clinically detectable junctional problems. The stem survival rate, with any stem revision as the endpoint, at 12 years was 96.6%. No significant difference was observed in the functional and radiological outcomes beween the Ti-Ti and nonmodular groups. CONCLUSIONS: The Ti-Ti modular neck femoral stem had comparable results with broadly used nonmodular femoral stems; hence, it can be a reliable option in primary total hip arthroplasty. However, in terms of the modularity itself of the modular neck femoral stem, whether the modular neck femoral stem is useful in uncomplicated primary total hip arthroplasty is unclear.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Artroplastia de Quadril/efeitos adversos , Artroplastia de Quadril/métodos , Titânio , Desenho de Prótese , Estudos Retrospectivos , Reoperação , Seguimentos , Falha de Prótese
3.
Artigo em Inglês | MEDLINE | ID: mdl-38569087

RESUMO

BACKGROUND: Little is known about the effect of surgical approach on return to braking after total hip arthroplasty (THA), and few studies have investigated braking after THA with modern surgical techniques and rehabilitation protocols. METHODS: In a prospective comparative design, we enrolled 65 patients who received right-sided primary THA at our institution from April 2018 through March 2020, 34 with a direct anterior approach (DAA) and 31 with a posterior approach (PA). Braking tests measuring brake reaction time (BRT) and brake pedal depression (BPD) were administered to patients preoperatively and at 1, 2, and 4 weeks postoperatively using a realistic driving simulator. BRT and BPD were compared between groups and preoperatively versus postoperatively using mixed-effects models. RESULTS: Preoperative BRT averaged 638 msec in the DAA group and 604 msec in the PA group (P = 0.31). At 1 week postoperatively, the DAA group had significantly prolonged BRT compared with preoperatively (694 msec, P = 0.02). No significant difference was observed in the PA group (633 msec, P = 0.31). Both groups had returned to baseline by 2 weeks, and both had significantly faster BRT at 4 weeks compared with preoperatively (583 msec for DAA, P = 0.01; 537 msec for PA, P < 0.001). BPD was similar between groups, and there were no significant differences between preoperative and postoperative BPD at any time point. CONCLUSIONS: With modern surgical techniques, BRT after right-sided THA returns to baseline levels approximately 2 weeks after surgery. There seems to be a quicker return to preoperative BRT observed in patients with a PA.


Assuntos
Artroplastia de Quadril , Condução de Veículo , Humanos , Artroplastia de Quadril/métodos , Estudos Prospectivos , Tempo de Reação , Complicações Pós-Operatórias
4.
Sci Rep ; 14(1): 8332, 2024 04 09.
Artigo em Inglês | MEDLINE | ID: mdl-38594498

RESUMO

Augmented reality (AR) has been used for navigation during total hip arthroplasty (THA). AR computed tomography (CT)-based navigation systems and AR-based portable navigation systems that use smartphones can also be used. This study compared the accuracy of cup insertion during THA using AR-CT-based and portable AR-based navigation systems. Patients with symptomatic hip disease who underwent primary THA in the supine position using both AR CT-based and portable AR-based navigation systems simultaneously between October 2021 and July 2023 were included. The primary outcome of this study was the absolute difference between cup angles in the intraoperative navigation record and those measured on postoperative CT. The secondary outcome was to determine the factors affecting the absolute value of the navigation error in radiographic inclination (RI) and radiographic anteversion (RA) of the cup, including sex, age, body mass index, left or right side, approach, and preoperative pelvic tilt. This study included 94 consecutive patients. There were 11 men and 83 women, with a mean age of 68 years. The mean absolute errors of RI were 2.7° ± 2.0° in the AR CT-based and 3.3° ± 2.4° in the portable AR-based navigation system. The mean absolute errors of RA were 2.5° ± 2.1° in the AR CT-based navigation system and 2.3° ± 2.2° in the portable AR-based navigation system. No significant differences were observed in RI or RA of the cup between the two navigation systems (RI: p = 0.706; RA: p = 0.329). No significant factors affected the absolute value of the navigation errors in RI and RA. In conclusion, there were no differences in the accuracy of cup insertion between the AR CT-based and portable AR-based navigation systems.


Assuntos
Artroplastia de Quadril , Realidade Aumentada , Prótese de Quadril , Cirurgia Assistida por Computador , Masculino , Humanos , Feminino , Idoso , Artroplastia de Quadril/métodos , Tomografia Computadorizada por Raios X , Cirurgia Assistida por Computador/métodos , Acetábulo/cirurgia
5.
BMC Musculoskelet Disord ; 25(1): 276, 2024 Apr 10.
Artigo em Inglês | MEDLINE | ID: mdl-38600475

RESUMO

BACKGROUND: Traditional total hip arthroplasty (THA) using the direct anterior approach (DAA) requires a hip extension. This study aimed to compare the clinical outcomes of patients undergoing THA with DAA using either the no hip extension (NHE) or the traditional hip extension (THE) strategy. METHODS: A retrospective analysis of demographics, clinical and radiological outcomes, and occurrence of complications was performed using data from 123 patients treated between January 2020 and November 2021. The patients were categorised into two groups: NHE (84 patients) and THE (39 patients). RESULTS: The NHE group exhibited shorter operative time and had more male participants with higher ages. Comparable outcomes were observed in the visual analogue scale, Harris Hip, and Oxford Hip scores at the final follow-up. Furthermore, complications were observed in the NHE and THE groups, including two and one greater trochanteric fractures and three and one transfusions, respectively. CONCLUSIONS: Compared to the THE, employing the NHE strategy during THA with DAA in elderly and young female patients resulted in comparable clinical outcomes with several advantages, such as favourable surgical time. The NHE method also exhibited good safety and effectiveness. Therefore, the NHE strategy may be a favourable option for elderly and young female patients.


Assuntos
Artroplastia de Quadril , Humanos , Masculino , Feminino , Idoso , Artroplastia de Quadril/efeitos adversos , Artroplastia de Quadril/métodos , Estudos Retrospectivos , Resultado do Tratamento , Radiografia , Duração da Cirurgia
8.
Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi ; 38(4): 461-465, 2024 Apr 15.
Artigo em Chinês | MEDLINE | ID: mdl-38632067

RESUMO

Objective: To explore the method of accurately estimating the acetabular cup prosthesis coverage rate (hereinafter referred to as "cup coverage rate") in total hip arthroplasty (THA) based on X-ray films, and to determine the effective parameters that can be used to estimate the cup coverage rate. Methods: The three-dimensional printed pelvic models were established based on CT data of 16 healthy pelvis, and the acetabular prosthesis were implanted according to conventional THA procedure. The length and width of the uncovered area of the acetabular cup prosthesis were measured by a modified X-ray recording method with a rotating C-arm X-ray machine, and the cup coverage rate was calculated. Then the differences among the traditional anteroposterior X-ray recording method, the modified method, and actual measurement on pelvic model were statistically analyzed. The correlation between the area of the uncovered area of the prosthesis and its width and length was analyzed by using multiple linear regression analysis. Results: The cup coverage rates of traditional method, modified method, and actual measurement were 78.22%±3.36%, 86.74%±3.61%, and 89.62%±2.62%, respectively, with significant differences ( P<0.05). The results of multiple linear regression analysis showed that the width and length were positively linear with the uncovered area of the prosthesis, and the regression equation was as follows: uncovered area of the prosthesis=-21.192+0.248×width+0.140×length, and the coefficient of determination R 2=0.857, P<0.001. Conclusion: Compared with the traditional method, the modified method can more accurately evaluate the cup coverage rate during THA, and the width of the uncovered area of the prosthesis can be used as an effective reference for the cup coverage rate.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Artroplastia de Quadril/métodos , Acetábulo/cirurgia , Filme para Raios X , Tomografia Computadorizada por Raios X/métodos
9.
Acta Orthop ; 95: 174-179, 2024 Apr 17.
Artigo em Inglês | MEDLINE | ID: mdl-38629902

RESUMO

BACKGROUND AND PURPOSE: Concerns have emerged regarding elevated levels of cobalt and chromium in patients with metal-on-metal megaprostheses. This prospective study aims to identify systemic cobalt and chromium levels in metal-on-polyethylene knee and hip megaprostheses and their associations with other factors. METHODS: 56 patients underwent knee or hip megaprosthesis surgery at 2 sarcoma centers. Serum cobalt and chromium levels were measured preoperatively and thrice within the first year using inductively coupled plasma mass spectrometry. RESULTS: A statistically significant difference in serum cobalt levels (1.4 ppb; 95% confidence interval [CI] 0.0-3.3) was observed 1 year after knee megaprosthesis surgery compared with preoperative levels. In contrast no difference in chromium levels was observed after 1 year compared with preoperative levels (0.05 ppb; CI 0.0-0.8). An association between younger age, higher eGFR, and increased cobalt levels was observed. No significant correlations were found between ion levels and resection length or the number of modular connections. CONCLUSION: We found elevated serum ion levels in metal-on-polyethylene knee megaprostheses in contrast to metal-on-polyethylene hip megaprostheses. Furthermore, a positive correlation between cobalt and chromium levels, and between cobalt and eGFR was identified, along with a negative correlation between cobalt and age. This study highlights the importance of monitoring systemic cobalt and chromium levels in patients with megaprostheses.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Humanos , Cobalto , Estudos Prospectivos , Polietileno , Estudos de Coortes , Prótese de Quadril/efeitos adversos , Metais , Cromo , Artroplastia de Quadril/métodos , Desenho de Prótese
10.
Clin Orthop Surg ; 16(2): 210-216, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38562629

RESUMO

Background: As the population ages, the rates of hip diseases and fragility fractures are increasing, making total hip arthroplasty (THA) one of the best methods for treating elderly patients. With the increasing number of THA surgeries and diverse surgical methods, there is a need for standard evaluation protocols. This study aimed to use deep learning algorithms to classify THA videos and evaluate the accuracy of the labelling of these videos. Methods: In our study, we manually annotated 7 phases in THA, including skin incision, broaching, exposure of acetabulum, acetabular reaming, acetabular cup positioning, femoral stem insertion, and skin closure. Within each phase, a second trained annotator marked the beginning and end of instrument usages, such as the skin blade, forceps, Bovie, suction device, suture material, retractor, rasp, femoral stem, acetabular reamer, head trial, and real head. Results: In our study, we utilized YOLOv3 to collect 540 operating images of THA procedures and create a scene annotation model. The results of our study showed relatively high accuracy in the clear classification of surgical techniques such as skin incision and closure, broaching, acetabular reaming, and femoral stem insertion, with a mean average precision (mAP) of 0.75 or higher. Most of the equipment showed good accuracy of mAP 0.7 or higher, except for the suction device, suture material, and retractor. Conclusions: Scene annotation for the instrument and phases in THA using deep learning techniques may provide potentially useful tools for subsequent documentation, assessment of skills, and feedback.


Assuntos
Artroplastia de Quadril , Aprendizado Profundo , Fraturas Ósseas , Prótese de Quadril , Humanos , Idoso , Artroplastia de Quadril/métodos , Acetábulo/cirurgia , Fraturas Ósseas/cirurgia , Fêmur/cirurgia , Estudos Retrospectivos
11.
PLoS One ; 19(4): e0300460, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38635750

RESUMO

BACKGROUND: Total hip arthroplasty (THA) is a common procedure following which postoperative visits are important to optimize outcomes. The associated global billing period includes the 90 postoperative days (or approximately 13 weeks), during which professional billing is included with the surgery itself. The current study assessed clinical practice patterns relative to the global billing period. METHODS: Using the PearlDiver M91Ortho dataset, the incidence and timing of Evaluation and Management (E&M) codes in the 26 weeks following THA were assessed. The follow-up visits within and beyond the global billing period, and those conducted by surgeons versus non-surgeon advanced practice providers (APPs) were determined. RESULTS: 77,843 THAs were identified. Follow-up visits peaked at postoperative weeks 3, 7, and 14. The greatest week-to-week variation in the number of follow-ups was from weeks 13 to 14 immediately following the global billing period (representing a greater than 4-fold increase in visits.) During the first 13 postop weeks, 73.8% of patients were seen by orthopedic surgeons (as opposed to APPs). In the following 13 weeks, a significantly greater percentage of visits were with surgeons (86.8%, p<0.0001). CONCLUSIONS: Following the THA global billing period, there was marked increase in the number of follow-ups and transition to a greater percentage being performed by the surgeons. These results provide interesting insight into the potential impact of the billing structure on how practice is pursued.


Assuntos
Artroplastia de Quadril , Cirurgiões Ortopédicos , Cirurgiões , Humanos , Artroplastia de Quadril/métodos , Seguimentos , Período Pós-Operatório , Estudos Retrospectivos
12.
J Robot Surg ; 18(1): 160, 2024 Apr 05.
Artigo em Inglês | MEDLINE | ID: mdl-38578350

RESUMO

Robotic assisted (RA) total hip arthroplasty (THA) offers improved acetabular component placement and radiographic outcomes, but inconsistent assessment methods of its learning curves render the evaluation of adopting novel platforms challenging. Therefore, we conducted a systematic review to assess the learning curve associated with RA-THA, both tracking a surgeon's performance across initial cases and comparing their performance to manual THA (M-THA). PubMed, MEDLINE, EBSCOhost, and Google Scholar were searched on June 16, 2023, to identify studies published between January 1, 2000 and June 16, 2023 (PROSPERO registration: CRD42023437339). The query yielded 655 unique articles, which were screened for eligibility. The final analysis included 11 articles, evaluating 1351 THA procedures. Risk of bias was assessed via the Methodological Index for Nonrandomized Studies (MINORS) tool. The mean MINORS score was 21.3 ± 0.9. RA-THA provided immediate improvements in acetabular component placement accuracy and radiographic outcomes compared to M-THA, with little to no experience required to achieve peak proficiency. A modest learning curve (12-17 cases) was associated with operative time, which was elevated compared to M-THA (+ 9-13 min). RA-THA offers immediate advantages to M-THA for component placement accuracy and radiographic outcomes. Surgeons should expect to experience increased operative times, which become less pronounced or equivalent to M-THA after a modest caseload.


Assuntos
Artroplastia de Quadril , Procedimentos Cirúrgicos Robóticos , Cirurgia Assistida por Computador , Humanos , Artroplastia de Quadril/métodos , Curva de Aprendizado , Procedimentos Cirúrgicos Robóticos/métodos , Acetábulo/diagnóstico por imagem , Acetábulo/cirurgia , Cirurgia Assistida por Computador/métodos
13.
Zhongguo Gu Shang ; 37(2): 166-72, 2024 Feb 25.
Artigo em Chinês | MEDLINE | ID: mdl-38425068

RESUMO

OBJECTIVE: To explore the clinical efficacy of high hip center technique total hip arthroplasty (THA) for Crowe Ⅱand Ⅲ developmental dysplasia of hip (DDH) and severe hip osteoarthritis (HOA). METHODS: From January 2018 to January 2020, 74 patients with Crowe typeⅡand Ⅲ DDH and severe HOA were admitted, and 37 cases of anatomical hip center reconstruction were taken as control group, including 7 males and 30 females, aged from 42 to 65 years old with an average of (58.40±4.98) years old, body mass index (BMI) ranged from 18 to 29 kg·m-2 with an average of (23.02±2.21) kg·m-2. Thirty-seven routine high hip center technical reconstruction were performed as study group, including 5 males and 32 females, aged from 41 to 65 years old with an average of (57.31±5.42) years old, BMI ranged from 18 to 29 kg·m-2 with an average of (23.14±2.07) kg·m-2. The patients presented with hip pain, limited function and range of motion, and gait instability before surgery. All patients underwent THA, the control group underwent intraoperative anatomical hip center reconstruction, and the study group underwent intraoperative high hip joint reconstruction. The perioperative indicators of the two groups were compared. The hip joint function, balance function and gait of the patients were evaluated before surgery, 3 months, 6 months, and 12 months after surgery. The length difference of both lower limbs, horizontal distance of rotation center, vertical distance of rotation center and femoral eccentricity were measured before operation and 1 year after operation. The incidence of complications in the two groups during the operation and postoperative follow-up was counted. RESULTS: The operation time of the study group was shorter than that of the control group, and the intraoperative blood loss was less than that of the control group (P<0.05). After 12-months follow-up, 1 was lost to followvup in study group and 2 were lost to follow-up in control group. The Harris scores and Berg balance scale(BBS), pace, stride frequency and single step length in the study group were higher than those in the control group at 3 months and 6 months after operation (P<0.05);there was no statistically significant difference between the two groups in the indexes 12 months after operation (P>0.05). The vertical distance of the center of rotation of the study group was greater than that of the control group 12 months after operation (P<0.05), and there was no significant difference in the length difference of the lower limbs, the horizontal distance of the center of rotation, and the femoral eccentricity between two groups (P>0.05). There were no complications in either group. CONCLUSION: The long-term effects of THA in patients with DDH and severe HOA were similar between the two central hip reconstruction methods, and the safety was good, and the high hip central reconstruction technique could shorten the operation time and reduce the amount of intraoperative blood loss.At the same time, it has certain advantages in early recovery of hip joint function, balance function and walking function of patients.


Assuntos
Artroplastia de Quadril , Luxação Congênita de Quadril , Osteoartrite do Quadril , Masculino , Feminino , Humanos , Adulto , Pessoa de Meia-Idade , Idoso , Artroplastia de Quadril/métodos , Osteoartrite do Quadril/cirurgia , Luxação Congênita de Quadril/cirurgia , Perda Sanguínea Cirúrgica , Estudos Retrospectivos , Resultado do Tratamento
14.
Bone Joint J ; 106-B(4): 372-379, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38555938

RESUMO

Aims: Histology is widely used for diagnosis of persistent infection during reimplantation in two-stage revision hip and knee arthroplasty, although data on its utility remain scarce. Therefore, this study aims to assess the predictive value of permanent sections at reimplantation in relation to reinfection risk, and to compare results of permanent and frozen sections. Methods: We retrospectively collected data from 226 patients (90 hips, 136 knees) with periprosthetic joint infection who underwent two-stage revision between August 2011 and September 2021, with a minimum follow-up of one year. Histology was assessed via the SLIM classification. First, we analyzed whether patients with positive permanent sections at reimplantation had higher reinfection rates than patients with negative histology. Further, we compared permanent and frozen section results, and assessed the influence of anatomical regions (knee versus hip), low- versus high-grade infections, as well as first revision versus multiple prior revisions on the histological result at reimplantation. Sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), chi-squared tests, and Kaplan-Meier estimates were calculated. Results: Overall, the reinfection rate was 18%. A total of 14 out of 82 patients (17%) with positive permanent sections at reimplantation experienced reinfection, compared to 26 of 144 patients (18%) with negative results (p = 0.996). Neither permanent sections nor fresh frozen sections were significantly associated with reinfection, with a sensitivity of 0.35, specificity of 0.63, PPV of 0.17, NPV of 0.81, and accuracy of 58%. Histology was not significantly associated with reinfection or survival time for any of the analyzed sub-groups. Permanent and frozen section results were in agreement for 91% of cases. Conclusion: Permanent and fresh frozen sections at reimplantation in two-stage revision do not serve as a reliable predictor for reinfection.


Assuntos
Artroplastia de Quadril , Artroplastia do Joelho , Prótese de Quadril , Prótese do Joelho , Infecções Relacionadas à Prótese , Humanos , Artroplastia do Joelho/efeitos adversos , Artroplastia do Joelho/métodos , Prótese do Joelho/efeitos adversos , Artroplastia de Quadril/efeitos adversos , Artroplastia de Quadril/métodos , Prótese de Quadril/efeitos adversos , Infecções Relacionadas à Prótese/diagnóstico , Infecções Relacionadas à Prótese/etiologia , Infecções Relacionadas à Prótese/cirurgia , Estudos Retrospectivos , Reinfecção , Articulação do Joelho/cirurgia , Reoperação/métodos
15.
Bone Joint J ; 106-B(4): 352-358, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38555941

RESUMO

Aims: Dislocation remains a leading cause of failure following revision total hip arthroplasty (THA). While dual-mobility (DM) bearings have been shown to mitigate this risk, options are limited when retaining or implanting an uncemented shell without modular DM options. In these circumstances, a monoblock DM cup, designed for cementing, can be cemented into an uncemented acetabular shell. The goal of this study was to describe the implant survival, complications, and radiological outcomes of this construct. Methods: We identified 64 patients (65 hips) who had a single-design cemented DM cup cemented into an uncemented acetabular shell during revision THA between 2018 and 2020 at our institution. Cups were cemented into either uncemented cups designed for liner cementing (n = 48; 74%) or retained (n = 17; 26%) acetabular components. Median outer head diameter was 42 mm. Mean age was 69 years (SD 11), mean BMI was 32 kg/m2 (SD 8), and 52% (n = 34) were female. Survival was assessed using Kaplan-Meier methods. Mean follow-up was two years (SD 0.97). Results: There were nine cemented DM cup revisions: three for periprosthetic joint infection, three for acetabular aseptic loosening from bone, two for dislocation, and one for a broken cup-cage construct. The two-year survivals free of aseptic DM revision and dislocation were both 92%. There were five postoperative dislocations, all in patients with prior dislocation or abductor deficiency. On radiological review, the DM cup remained well-fixed at the cemented interface in all but one case. Conclusion: While dislocation was not eliminated in this series of complex revision THAs, this technique allowed for maximization of femoral head diameter and optimization of effective acetabular component position during cementing. Of note, there was only one failure at the cemented interface.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Luxações Articulares , Humanos , Feminino , Idoso , Masculino , Falha de Prótese , Desenho de Prótese , Estudos Retrospectivos , Acetábulo/cirurgia , Artroplastia de Quadril/métodos , Luxações Articulares/cirurgia , Reoperação/métodos , Seguimentos
16.
Bone Joint J ; 106-B(4): 344-351, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38555949

RESUMO

Aims: Revision total hip arthroplasty in patients with Vancouver type B3 fractures with Paprosky type IIIA, IIIB, and IV femoral defects are difficult to treat. One option for Paprovsky type IIIB and IV defects involves modular cementless, tapered, revision femoral components in conjunction with distal interlocking screws. The aim of this study was to analyze the rate of reoperations and complications and union of the fracture, subsidence of the stem, mortality, and the clinical outcomes in these patients. Methods: A total of 46 femoral components in patients with Vancouver B3 fractures (23 with Paprosky type IIIA, 19 with type IIIB, and four with type IV defects) in 46 patients were revised with a transfemoral approach using a modular, tapered, cementless revision Revitan curved femoral component with distal cone-in-cone fixation and prospectively followed for a mean of 48.8 months (SD 23.9; 24 to 112). The mean age of the patients was 80.4 years (66 to 100). Additional distal interlocking was also used in 23 fractures in which distal cone-in-cone fixation in the isthmus was < 3 cm. Results: One patient (2.2%) died during the first postoperative year. After six months, 43 patients (93.5%) had osseous, and three had fibrous consolidation of the fracture and the bony flap, 42 (91.3%) had bony ingrowth and four had stable fibrous fixation of the stem. No patient had radiolucency around the interlocking screws and no screw broke. One patient had non-progressive subsidence and two had a dislocation. The mean Harris Hip Score increased from of 57.8 points (SD 7.9) three months postoperatively to 76.1 points (SD 10.7) 24 months postoperatively. Conclusion: The 2° tapered, fluted revision femoral component with distal cone-in-cone-fixation, combined with additional distal interlocking in patients with bony deficiency at the isthmus, led to reproducibly good results in patients with a Vancouver B3 fracture and Paprosky type IIIA, IIIB, and IV defects with regard to union of the fracture, subsidence or loosening of the stem, and clinical outcomes.


Assuntos
Artroplastia de Quadril , Fraturas do Fêmur , Prótese de Quadril , Fraturas Periprotéticas , Humanos , Idoso de 80 Anos ou mais , Artroplastia de Quadril/métodos , Fraturas Periprotéticas/cirurgia , Fraturas Periprotéticas/etiologia , Prótese de Quadril/efeitos adversos , Resultado do Tratamento , Desenho de Prótese , Reoperação/métodos , Fraturas do Fêmur/cirurgia , Estudos Retrospectivos
17.
Am J Sports Med ; 52(5): 1153-1164, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38476016

RESUMO

BACKGROUND: Arthroscopic treatment of femoroacetabular impingement (FAI) and symptomatic labral tears confers short- to midterm benefits, yet further long-term evidence is needed. Moreover, despite the physiological and biomechanical significance of the chondrolabral junction (CLJ), the clinical implications of damage to this transition zone remain understudied. PURPOSE: To (1) report minimum 8-year survivorship and patient-reported outcome measures after hip arthroscopy for FAI and (2) characterize associations between outcomes and patient characteristics (age, body mass index, sex), pathological parameters (Tönnis angle, alpha angle, type of FAI, CLJ breakdown), and procedures performed (labral management, FAI treatment, microfracture). STUDY DESIGN: Cohort study; Level of evidence, 3. METHODS: This retrospective cohort study included patients who underwent primary hip arthroscopy for symptomatic labral tears secondary to FAI by a single surgeon between 2002 and 2013. All patients were ≥18 years of age with minimum 8-year follow-up and available preoperative radiographs. The primary outcome was conversion to total hip arthroplasty (THA), and secondary outcomes included revision arthroscopy, patient-reported outcome measures, and patient satisfaction. CLJ breakdown was assessed using the Beck classification. Kaplan-Meier estimates and weighted Cox regression were used to estimate 10-year survivorship (no conversion to THA) and identify risk factors associated with THA conversion. RESULTS: In this study of 174 hips (50.6% female; mean age, 37.8 ± 11.2 years) with mean follow-up of 11.1 ± 2.5 years, the 10-year survivorship rate was 81.6% (95% CI, 75.9%-87.7%). Conversion to THA occurred at a mean 4.7 ± 3.8 years postoperatively. Unadjusted analyses revealed several variables significantly associated with THA conversion, including older age; higher body mass index; higher Tönnis grade; labral debridement; and advanced breakdown of the CLJ, labrum, or articular cartilage. Survivorship at 10 years was inferior in patients exhibiting severe (43.6%; 95% CI, 31.9%-59.7%) versus mild (97.9%; 95% CI, 95.1%-100%) breakdown of the CLJ (P < .001). Multivariable analysis identified worsening CLJ breakdown (weighted hazard ratio per 1-unit increase, 6.41; 95% CI, 3.11-13.24), older age (1.09; 95% CI, 1.04-1.14), and higher Tönnis grade (4.59; 95% CI, 2.13-9.90) as independent negative prognosticators (P < .001 for all). CONCLUSION: Although most patients achieved favorable minimum 8-year outcomes, several pre- and intraoperative factors were associated with THA conversion; of these, worse CLJ breakdown, higher Tönnis grade, and older age were the strongest predictors.


Assuntos
Artroplastia de Quadril , Impacto Femoroacetabular , Humanos , Feminino , Adulto , Pessoa de Meia-Idade , Masculino , Artroplastia de Quadril/métodos , Articulação do Quadril/cirurgia , Seguimentos , Estudos de Coortes , Estudos Retrospectivos , Artroscopia/métodos , Resultado do Tratamento , Impacto Femoroacetabular/diagnóstico por imagem , Impacto Femoroacetabular/cirurgia , Impacto Femoroacetabular/complicações
18.
J Orthop Traumatol ; 25(1): 12, 2024 Mar 02.
Artigo em Inglês | MEDLINE | ID: mdl-38430413

RESUMO

BACKGROUND: Alumina particles from the grit blasting of Ti-alloy stems are suspected to contribute to aseptic loosening. An alumina-reduced stem surface was hypothesized to improve osseointegration and show comparable short-term outcomes to those of a standard stem. METHODS: In this prospective, double-blind, randomized trial, 26 standard (STD) and 27 experimental new technology (NT) stems were implanted. The latter were additionally treated by acid etching and ice blasting to remove alumina particles from the grit-blasting process. Follow-up occurred at 12 and 24 months. Bone mineral density (BMD) around the stem was measured by a dual-energy x-ray absorptiometry device (DEXA). Radiographs were reviewed for alterations. Clinical scoring comprised the Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) and the Harris Hip Score (HHS). Survival rates were calculated up to 50 months. RESULTS: Lower mean BMD and more severe cortical hypertrophies were found in the NT group. At 12 months, radiolucent lines were observed mostly in the metaphyseal zone for both groups, with a progression tendency in the NT group at 24 months. At 12 months, pain scores and the WOMAC total and physical activity scores were significantly lower in the NT group, without any differences thereafter. The number of NT stem revisions amounted to 6 (24%) and 11 (41%) at 24 and 50 months, respectively. CONCLUSION: In the NT group, unexpected catastrophic failure rates of 41% caused by early aseptic loosening were noted within 50 months. Compared with the STD stems, NT stems lead to poor clinical and radiographic results. LEVEL OF EVIDENCE: II. TRIAL REGISTRATION: NCT05053048.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Humanos , Absorciometria de Fóton , Óxido de Alumínio , Artroplastia de Quadril/métodos , Seguimentos , Estudos Prospectivos , Desenho de Prótese , Falha de Prótese , Resultado do Tratamento , Método Duplo-Cego
19.
Bone Joint J ; 106-B(3 Supple A): 104-109, 2024 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-38425294

RESUMO

Aims: Femoral component anteversion is an important factor in the success of total hip arthroplasty (THA). This retrospective study aimed to investigate the accuracy of femoral component anteversion with the Mako THA system and software using the Exeter cemented femoral component, compared to the Accolade II cementless femoral component. Methods: We reviewed the data of 30 hips from 24 patients who underwent THA using the posterior approach with Exeter femoral components, and 30 hips from 24 patients with Accolade II components. Both groups did not differ significantly in age, sex, BMI, bone quality, or disease. Two weeks postoperatively, CT images were obtained to measure acetabular and femoral component anteversion. Results: The mean difference in femoral component anteversion between intraoperative and postoperative CT measurements (system accuracy of component anteversion) was 0.8° (SD 1.8°) in the Exeter group and 2.1° (SD 2.3°) in the Accolade II group, respectively (p = 0.020). The mean difference in anteversion between the plan and the postoperative CT measurements (clinical accuracy of femoral component anteversion) was 1.2° (SD 3.6°) in the Exeter group, and 4.2° (SD 3.9°) in the Accolade II group (p = 0.003). No significant differences were found in acetabular component inclination and anteversion; however, the clinical accuracy of combined anteversion was significantly better in the Exeter group (0.6° (SD 3.9°)) than the Accolade II group (3.6° (SD 4.1°)). Conclusion: The Mako THA system and software helps surgeons control the femoral component anteversion to achieve the target angle of insertion. The Exeter femoral component, inserted using Mako THA system, showed greater precision for femoral component and combined component anteversion than the Accolade II component.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Procedimentos Cirúrgicos Robóticos , Humanos , Acetábulo/diagnóstico por imagem , Acetábulo/cirurgia , Artroplastia de Quadril/métodos , Estudos Retrospectivos , Tomografia Computadorizada por Raios X , Masculino , Feminino
20.
Bone Joint J ; 106-B(3 Supple A): 17-23, 2024 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-38425296

RESUMO

Aims: Professional dancers represent a unique patient population in the setting of hip arthroplasty, given the high degree of hip strength and mobility required by their profession. We sought to determine the clinical outcomes and ability to return to professional dance after total hip arthroplasty (THA) or hip resurfacing arthroplasty (HRA). Methods: Active professional dancers who underwent primary THA or HRA at a single institution with minimum one-year follow-up were included in the study. Primary outcomes included the rate of return to professional dance, three patient-reported outcome measures (PROMs) (modified Harris Hip Score (mHHS), Hip disability and Osteoarthritis Outcome Score for Joint Replacement (HOOS-JR), and Lower Extremity Activity Scale (LEAS)), and postoperative complications. Results: A total of 49 hips in 39 patients (mean age 56 years (SD 13); 80% female (n = 39)) were included. Mean follow-up was 4.9 years (SD 5.1). Of these 49 hips, 37 THAs and 12 HRAs were performed. In all, 96% of hips returned to professional dance activities postoperatively. With regard to PROMs, there were statistically significant improvements in mHHS, HOOS-JR, and LEAS from baseline to ≥ one year postoperatively. There were complications in 7/49 hips postoperatively (14%), five of which required revision surgery (10%). There were no revisions for instability after the index procedure. Two complications (5.4%) occurred in hips that underwent THA compared with five (42%) after HRA (p = 0.007), though the difference by procedure was not significantly different when including only contemporary implant designs (p = 0.334). Conclusion: Active professional dancers experienced significant improvements in functional outcome scores after THA or HRA, with a 96% rate of return to professional dance. However, the revision rate at short- to mid-term follow-up highlights the challenges of performing hip arthroplasty in this demanding patient population. Further investigation is required to determine the results of THA versus HRA using contemporary implant designs in these patients.


Assuntos
Artroplastia de Quadril , Dança , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Artroplastia de Quadril/efeitos adversos , Artroplastia de Quadril/métodos , Reoperação , Resultado do Tratamento , Adulto , Idoso
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...